Price Check Guarantee

Price Check Guarantee

Nationwide Installations

Nationwide Installations

Next Day Deliveries

Next Day Deliveries

Free Expert Advice

Free Expert Advice

Free Site Survey

Remote Reboot Switches

These remote reboot power switches provide the ability to remotely control the power to servers and other connected devices over an IP network connection or the internet using and HTTP/HTTPS browser by issuing a reboot command. Remote power control switches reduce the need to visit sites when it is necessary to reboot or recycle the connected loads including IT servers.

Power section(s) Dropdown arrow sprite

Outlet NumberSubmenu expander (reset)
Outlet TypesSubmenu expander (reset)
Inlet TypesSubmenu expander (reset)
ConnectivitySubmenu expander (reset)
Form FactorsSubmenu expander (reset)
SensorsSubmenu expander (reset)
BrandsSubmenu expander (reset)
Digital Inputs / Digital OutputsSubmenu expander (reset)
Control FeaturesSubmenu expander (reset)

Netio Remote Reboot Power Switch

These products can be used as a reboot switch to remotely shutdown and reboot a connected load over a network LAN or http/https connection.

Netio Reboot Switches

Range LAN RJ45 Ports WiFi IQRF Outlets ZCS/ZVS Metering/Metrics Web-based Management RS232 Port Netio Cloud Scheduler WatchDog M2M APIs
PowerPDU 4KS PDUs 1 4 x C13 IEC320 ZCS Yes Yes Yes Yes Yes 10
PowerPDU 4C PDUs 2 4 x C13 IEC320 ZCS Yes Yes Yes Yes Yes Yes 13
PowerPDU 4PS PDUs 1 4 x C13 IEC320 ZVS Yes Yes Yes XML, JSON, URL API, Modbus/TCP, Telnet, MQTT-flex, SNMPv1
PowerPDU 8QS PDUs 1 8 x C13 IEC320 ZVS Yes Yes Yes Yes Yes 10
PowerBOX 3Px Power Strips 1 3 x UK BS1363 ZVS Yes Yes Yes XML, JSON, URL API, Modbus/TCP, Telnet, MQTT-flex, SNMPv1
PowerBOX-4Kx Power Strips 1 4 x UK BS1363 ZCS Yes, inc local power generation Yes Yes Yes XML, JSON, URL API, Modbus/TCP, Telnet, MQTT-flex, SNMPv1
PowerCable-MODBUS Int 1 x UK BS1363 ZCS Yes/6 Yes Yes Yes MODBUS/TCP
PowerCable-REST Int 1 x UK BS1363 ZCS Yes/6 Yes Yes Yes XML, JSON, URL API
PowerCable-IQRF Int 1 x UK BS1363 ZCS Yes/6 Yes IQRF
PowerCable-MQTT Int 1 x UK BS1363 ZCS Yes/6 Yes Yes Yes MQTT, MQTT-Flex, HTTP Push (XML, JSON)
NETIO-4ALL Yes Ext 4 x Schuko Yes/22 Yes Yes Yes Yes 13
NETIO-4 Yes Ext 4 x Schuko Yes Yes Yes Yes 13

Note: ZCS stands for Zero Current Switching. ZVS stands for Zero Voltage Switching.

Zero Current Switching (ZCS)

The ZVS function uses a relay contact and ensures it is closed at zero voltage and opened when zero current flows through the relay. This has several advantages:

  • Inrush currents are reduced which can reduce the working life of the relay
  • High inrush currents are reduced which could place extra load on upstream branch circuit breakers
  • Less impact on the working life of the connected loads when switched ON or OFF
  • Significantly reduced electromagnetic interference created by repeated switching ON and OFF

There is a difference between ZCS and ZVS, which stands for Zero Voltage Switching.

  • Zero Current Switching is a universal solution for all types of load but it is more difficult to implement than ZVS. It requires CosĪ† (or TruePF, Power Factor) measurements in order to analyse the phase shift between the current and the voltage waveforms.
  • Zero Voltage Switching simply switches when the voltage is zero. ZVS is easier to implement and works well for controlling switching power supplies but is not suitable for controlling inductive loads including transformers and motors.

For more information on our intelligent power monitoring and smart remote power control switches please see the individual switch products or contact our projects team.

Earn-sre-points

Earn SRE points on all online purchases with double points on selected products

World Leading Brands
Manufacturer Independent Solutions