30kVA UPS Prices and Specifications

Three phase UPS systems available from Server Room Environments for the protection of server rooms and datacentres. The UPS are rated at 30kVA and their kW-rating will vary depending on the output power factor of the UPS. The UPS may offer parallel capability allowing two or more UPS to be configured for additional resilience into an N+X configuration. The range includes options for internal batteries and external extension packs to increase battery runtime.

Power section(s) Dropdown arrow sprite

UPS ApplicationsSubmenu expander (reset)
UPS Form FactorSubmenu expander (reset)
UPS Phases (In/Out)Submenu expander (reset)
UPS Runtime OptionsSubmenu expander (reset)
UPS SizesSubmenu expander (reset)
BrandsSubmenu expander (reset)
Battery TypesSubmenu expander (reset)

Electrical Installations

Server Room Environments provides a complete electrical installation service for 30kVA sized UPS systems by NICEIC certified electrical contractors. The installation service covers every aspect you could need in a UPS installation including:

  • Electrical Site Survey: to assess the electrical infrastructure and advise on any necessary electrical works to upgrade prior to the installation of a UPS system. This includes checking wiring and circuit breaker sizes, distribution arrangements and discrimination for fault clearance.
  • External UPS Bypass Switches: a maintenance bypass switch allows your UPS to be serviced without disruption to the connected load(s). Your UPS system may include an internal maintenance bypass switch. An external UPS bypass allows the system to be fully powered down and removed without load disruption. Bypass arrangements can be configured for single or parallel/redundant configurations.
  • Electrical Site Survey: on-site battery build may be necessary for UPS extended runtimes where the weights of the batteries or size of the cabinet are two large for delivery as a standard unit. The electrical installations team can provide full onsite battery builds using DC certified and trained engineers.
  • Server Rack Power Distribution: another key aspect of the installation of an uninterruptible power supply is distribution of the protected power from the output of the UPS to the load(s). The electrical installation will include distribution arrangements as required. This can include power cords with Commando type sockets run from a wall mounted sub-distribution board to each server cabinet into which a power distribution unit can be connected, to overhead cable trays and trunking, and any extra sockets or hardwired outlets required within the facility.
  • Remote Monitoring: your UPS system will most likely be connected to the local IP network for remote monitoring and control. The electrical installations team can provide IP sockets and cabling as required for the network connection.
  • Commissioning: commissioning is completed by a UPS manufacturer certified UPS engineer. If required, our electrical installation teams will arrange for load banks if site acceptance testing (SAT) is specified.

UPS Maintenance Contracts

A UPS maintenance contract is recommended with an annual preventative maintenance visit for this size of UPS system. The maintenance contract will include technical support, parts (excluding consumables) and labour and an emergency call out facility. The call out server levels include 4 clock hours, 8 working and 12 working hours.

UPS Battery Runtime Options

UPS battery runtime is dependent upon several factors including load size, battery charge percentage, battery age and ambient temperature. Our project managers can provide a calculated battery back-up time for your load and UPS system. The standard UPS battery is a valve regulated lead acid (VRLA) type with options for lithium-ion batteries available.

Transformerless and Transformer-based UPS Systems

Transformerless UPS operate can operate at high operating efficiencies over a wide load range (down to 25% typically) and are designed for server room and datacentre environments. Transformer-based UPS are designed to protect critical IT and industrial loads in harsher electrical environments and where there is more extreme power pollution requiring a Galvanic isolation solution. Where isolation is required, transformerless UPS can be installed with an additional isolation transformer.

UPS Brand Range Design
Borri INGENIO PLUS Transformerless
CertaUPS C800 Transformerless