The 40kVA INGENIO Plus three phase UPS system is a high efficiency power protection system designed for small to medium sized server rooms, telecoms and datacentres. The INGENIO PLUS is a transformerless UPS design with a compact footprint and can be installed in single or parallel/redundant configurations. The UPS system uses Green Conversion technology to provide high operating efficiencies, even at low loads and to optimise the working life of the connected battery set. The UPS has an input power factor of 0.99 and a low input current distortion, with a soft start feature to guarantee generator compatibility. Electrical installation costs are relatively low as infrastructure does not have to be oversized and the overall installation and maintenance space required is low due to the compact transformerless design. A common battery set can be used for parallel/redundant UPS configurations.
40kVA/40kW UPS System Features
- Online double conversion UPS, VFI-SS-111 classification as per IEC EN 62040-3
- Ultra-high efficiency mode providing up to 99% efficiency
- Full rated output power (pF=1) for optimal UPS sizing and utilization
- Full IGBT technology Transformer free design with electronic power factor correction
- Input power factor of 0.99 input power factor and a low THDi <3%
- Generator compatible and with a Cold restart option
- A range of communications options and protocols for remote monitoring
- Internal lead acid battery sets with optional battery cabinets for extended runtimes or lithium-on batteries
- Dynamic Charging Mode (DCM) for maximum versatility, long autonomies with a fast recharge times
- Intermittent battery charge, with adjustable cycles to optimise energy savings
- Automatic system and battery test function
Runtime Options
SKU | Description | UPS Dimensions | Extension Cabinet/Rack |
---|---|---|---|
ING+40 | UPS with no battery | 465W x 750D x 1230Hmm 140Kg | – |
ING+40-05 | 5 minutes | 465W x 750D x 1230H 315Kg | – |
ING+40-10 | 10 minutes | 465W x 750D x 1230H 140Kg | 505W x 750D x 1200Hmm 475Kg * |
ING+40-18 | 18 minutes | 465W x 750D x 1230H 320Kg | 505W x 750D x 1200Hmmm 475Kg * |
ING+40-20 | 20 minutes | 465W x 750D x 1230H 140Kg | 782W x 845D x 1670Hmm 705Kg * |
ING+40-30 | 30 minutes | 465W x 750D x 1230H 140Kg | 782W x 845D x 1670Hmm 1040Kg * |
ING+40-45 | 45 minutes | 465W x 750D x 1230H 140Kg | 910W x 855D x 1738Hmm 1220Kg (Rack) * |
ING+40-60 | 60 minutes | 465W x 750D x 1230H 140Kg | 900W x 805D x 1749Hmm 1460Kg (Rack) * |
- Note requires on-site battery build.